10.7 Liquified/Liquid Petroleum Gas (LPG)

The following safety devices should be fitted to any LPG system:

Many recreational craft are fitted with Liquid Petroleum Gas (LPG) installations and appliances, primarily in the form of cookers. LPG is supplied in pressurised cylinders and is usually propane, butane or a mixture of the two gases.

▪Manual Isolation valve on the

cylinder;

▪Fixed pressure regulator located

within the storage locker to provide a fixed working pressure to the consuming device;

When handled incorrectly, the dangers associated with LPG systems include fire, explosion, burns and asphyxiation, due to gas leakage from the system or accumulation of gas following flame failure in an appliance. Such incidents have caused loss of life and material damage on recreational craft.

▪A pressure relief device located on

or adjacent to the cylinder;

▪An automatic safety gas cut out

device located on the cylinder or adjacent to it, to cut off the gas supply in the event of a loss of pressure due to a gas leak;

Emergency Action In the event of a gas leak being detected, the following actions should be taken:

▪A manual shut-off valve located

adjacent to the appliance, but easily accessed for the purpose of operation;

Operational Safety, including at Marinas, and Maintenance

▪Gas detectors, located in the

▪Isolate the gas supply at the

space appliances are situated. Detectors should be located in bilge areas or at floor level to detect accumulating gas leakage. Alarms should be audible and arranged to automatically cut off the gas supply from the bottle;

bottle;

▪Extinguish all flames and

cigarettes. Do not operate any electrical equipment or switches;

▪Ventilate the space, being aware

that as the gas is heavier than air, it will sink into bilges;

▪Carbon Monoxide alarms and local

fire alarms should also be fitted in spaces containing cookers;

▪Be aware of the location of all fire

extinguishing equipment;

▪All gas safety isolation and safety

▪Do not operate the system until

devices should be clearly marked to indicate their function and the open and closed positions.

the fault has been corrected by a qualified technician.

Further information and advice is contained in Marine Notice No. 37 of 2017 (Use of liquefied petroleum gas (LPG) installations and systems on merchant vessels, fishing vessels, pleasure craft and other marine craft).

Only appliances designed for use in a marine environment should be installed on a vessel. The cooker should be fitted with a gas shut-off. Systems should be subject to annual maintenance by a qualified technician and all onboard alarms and shut-offs should be checked at least monthly when the vessel is in use.