1.5.2 Fire-Fighting Equipment
1.5.2 Fire-Fighting Equipment
The Merchant Shipping (Fire Protection) Rules 2023 (S.I. No. 379 of 2023) contain requirements in relation to ship construction, fire protection, fire detection and fire extinction and apply to certain larger recreational craft built on or after 1 September 1984.
Applicable legislation:
▪Merchant Shipping Fire Appliances
Rules.
The term “Fire Appliances” refers to items of fire-fighting equipment such as fire extinguishers, fire blankets, fire hoses and pumps, etc.
While there are different sets of Rules which may apply to a recreational craft depending on
Table D: Mandatory Fire Fighting Equipment
| Equipment Item | Boats 13.7 - 15 metres in length | Boats 15 – less than 21.34 metres in length and less than 150 tonnes | Boats of 21.34 metres in length and greater |
|---|---|---|---|
| Fire Extinguishers | |||
| 2 fire extinguishers or fire buckets (one with lanyard) | ✓ | ✓ | |
| 3 fire extinguishers or fire buckets (one with lanyard) | ✓ | ||
| 2 fire extinguishers suitable for use on oil fires, for boats with internal combustion engines fitted | ✓ | ✓ | ✓ |
| Fire Pumps/Hoses | |||
| Manual fire pump (hand operated) | ✓ | ✓ | |
| Dedicated fire pump sea suction | ✓ | ✓ | ✓ |
| Fire hose | ✓ | ✓ | |
| Fire hose nozzle (minimum diameter 6 mm) with jet and water spray | ✓ | ✓ | |
| Power driven fire pump | ✓* | ||
| Fire main and hydrant | ✓ | ||
| 2 fire hoses | ✓ | ||
| Fire hose spray nozzle for machinery spaces | ✓ | ||
| Fireman’s axe | ✓ |