5.1.1 Provision for Gas-Extinguishing System
5.1.1Provision for Gas-Extinguishing System In a vessel with a gas-extinguishing system, the boundary of the machinery space must be able to contain the fire-extinguishing medium, i.e., the space must be capable of being closed down in order that the fire-extinguishing medium cannot penetrate to any other part of the vessel, or outside the vessel. This arrangement includes the closure of ventilation systems and hatchways.
5.1.2Fire Prevention .1Glass portlight and deadlight arrangements, if fitted in the boundaries of machinery spaces, will
be accepted if they are in a sound condition but, if damaged, they must be blanked off. .2Fire hazardous items, such as petrol tanks and gas containers, must not be stowed in machinery
spaces.
.3Exhaust pipes and ducts must be adequately insulated to avoid igniting combustible materials and
must be protected from damage.
.4Areas surrounding stoves and cooking appliances must be adequately protected with non-
combustible materials.
.5A suitable fire extinguisher must be provided adjacent to any compartment containing a
permanent fuel oil tank. Petrol engines must be fitted in an enclosure with a suitable fireextinguishing system or portable fire extinguisher.
Page 33 · View in original PDF