4.1.7Pumping and Piping Systems

4.1.7.1Fuel Oil Installations .1Tanks will generally be accepted, provided that they are of sound and efficient construction and

safe in operation. Glass contents gauges, where fitted, must have self-closing valves at the base. Metal rods, or slotted covers, must protect sight gauges. .2Piping systems should be of sound construction, in a good state of repair and suitable for the

service intended. Flexible connections should be of an appropriate armoured fire-resistant metallic hose with screwed fittings and kept as short as practicable.

.3Where any existing fuel and hydraulic lines are replaced, they shall be constructed out of fire-

resistant material.

4.1.7.2Cooling Water Systems .1Provided that the piping and fittings are of sound construction and efficient in operation, the

cooling water system fitted in pre-2004 fishing vessels will be accepted until such time as the system is renewed, or the vessel is re-engined, when the following requirements are to be met:

a)Cooling water inlets for main and auxiliary machinery must be kept to a minimum and

comply with the requirements of sections 2.1.18 and 2.1.19 above. b)Sea inlet trunks or boxes built into the hull structure must be of such a design that they

remain below the waterline at all normal conditions of trim and heel and must be fitted with arrangements for purging of trapped air. c)The sea inlet pipe to the propulsion engine must be fitted with an accessible strainer.

d)Where a common sea main supplying a number of services is installed, each branch pipe

must be fitted with an easily accessible isolating valve, with open/closed indication. e)Vessels of 7m Loa and over, with a single sea water cooling supply to the propulsion

engine, must be fitted with an additional hose connection with a valve, whereby an

emergency supply of cooling water from a bilge or general service pump may be introduced in the event of blockage of the main sea inlet valve. .2Owners and Masters of vessels fitted with Refrigerated Sea Water Systems should ensure that

notices are displayed onboard highlighting the dangers of the inhalation of toxic gases from refrigerated seawater. Further information can be found in Marine Notice No. 43 of 2016 – “Fatal Incident Caused by the Inhalation of Toxic Gases Onboard a Fishing Vessel”.

4.1.7.3Bilge Pumping Systems .1Vessels must have an efficient bilge pumping arrangement fitted, with the number of pumps as

required by paragraph 4.1.7.4.1 below. .2Where applicable, each watertight compartment must have a bilge suction and each suction must

be fitted with a strum (filter).

.3Routine cleaning of bilges is recommended.

4.1.7.4Bilge Pumps .1Decked vessels of 7m Loa and over must have 1 hand and 1 power-driven bilge pump fitted. All

other vessels must have at least 1 hand bilge pump. .2The power-driven pump referred to in paragraph 4.1.7.4.1 may be the general service/deckwash

pump, provided that any sea connection to the pump is isolated from the bilge suction main by a switch cock or interlocked valve system, such that sea water cannot drain into the bilge main.

.3Flexible connections and hoses, where fitted, must be soundly constructed and operate efficiently,

and they should be readily accessible.

.4Where watertight bulkheads are fitted, means should be provided in the piping system to prevent

any leakage via the system from compartment to compartment.

.5Where a deckwash pump is also utilised for bilge suction purposes, means must be provided to

prevent flooding of any compartment from the sea inlet via the bilge main.

.6In all vessels, except where the bilge can be readily seen, an audible and visible bilge level alarm

must be fitted to indicate leakage of water into the machinery space. Indication should be at the helm or control position.

4.2Part B – Post-2004 fishing vessels

Pages 28–29 · View in original PDF