4.1.6Electrical Installations

4.1.6.1General .1The design and installation of electrical systems shall be such that the risk of fire and electrical

shock to operating personnel is minimised. .2Detailed guidance on the design and installation of electrical equipment is given in the following

documents. Where practicable, these regulations should be followed when rewiring or fitting additional circuits and equipment:

a)The Institution of Electrical Engineers (IEE) Regulations for the Electrical and Electronic

Equipment of Ships with Recommended Practice for their Implementation, 6th Edition 1990 and Supplement 1994. b)Marine Notice No. 58 of 2011 – “Electrical Systems in Small Craft”. c)ISO 10133 - Small Craft Electrical Equipment Extra-low-voltage D.C. Installations. d)ISO 13297 - Small Craft Electrical Equipment Alternating Current Installations.

.3Particular attention must be given to protection against water ingress and the effects of vibration.

.4All circuits must be clearly identified on switchboards and distribution boards, including service,

protective device rating, current carrying capacity and voltage values. Differing voltages should not be included in any one distribution board.

.5All circuits, except the main supply from the battery to the starter motor, and electrically driven

steering motors should be provided with electrical protection against overload and short circuit (i.e., fuses or circuit breakers should be installed). Steering motors should have an overload alarm in lieu of overload protection. Short circuit protection should be for not less than twice the total rated current of the steering motors in the circuit protected.

.6Cables which are not provided with electrical protection should be kept as short as possible and

be “short circuit proofed”, e.g., single core with an additional insulating sleeve over the insulation of each core. Normal marine cable (e.g., in compliance with BS 6883), which is single core will meet this recommendation without an additional sleeve, since it has both conductor insulation and a sheath.

.7In the event of failure of engine and charging systems, the battery capacity must be able to supply

the emergency lights for at least one hour.

.8The electrical generating system must have sufficient capacity in normal running conditions to

ensure the correct operation of all safety and navigation equipment including navigation and fishing lights, where fitted.

.9With regard to existing cable installations and to any additional cables fitted:

a)Cables should not be run below floor plate level except where this is necessary for

connections to underwater equipment, etc., in which case the cable should be run in conduit. b)Cables running through machinery spaces should not be secured with plastic clips. c)Cables running through fish holds should be fitted in conduit and cables should not be

secured directly to fuel or oil storage tanks. d)Cables should be of the correct current carrying capacity for their application. e)When selecting cables, particular attention should be given to environmental factors such

as temperature and contact with substances, e.g., polystyrene, which degrades P.V.C. insulation. .10Vessels should be fitted with an adequate cathodic protection system. Anodes should be

efficiently connected to the system and the hull, and not painted over.

4.1.6.2D.C. Systems Up To 24 volts .1Systems should be two wire.

.2Existing earthing systems will be accepted provided that the system is sound and efficient and that

no danger to the system or vessel may occur. Hull earth plates, if fitted, must be efficiently connected and not painted over.

.3Batteries should be fitted in enclosed boxes or trays with covers and provided with sufficient

ventilation to open air for the battery type. Battery boxes should be sited clear of heat sources

and the battery installation and ventilation should be in accordance with IEE Regulations and Marine Notice No. 58 of 2011 – “Electrical Systems in Small Craft”.

.4A battery cut-off switch double pole type should be fitted at each battery or bank. Systems such

as automatic bilge pumps or alarms for when the vessel is unattended should be connected before the cut-off switch.

4.1.6.3A.C. Systems .1Cables for A.C. systems must be kept separate from D.C. systems and must be run in separate

trays and conduits. .2Switchgear for A.C. systems must be fitted in switchboards and panels which are separate from

those containing D.C. systems. Systems and equipment must be clearly marked.

.3Switchgear and sockets must be so arranged as to prevent the fitting of low voltage equipment

and lamps into high voltage systems.

Pages 26–28 · View in original PDF