Hatches and Coamings

.3Hatchways in weather decks must be fitted with a weathertight closure to the requirements of

Acceptable Construction Rules. Weather deck hatch coamings are to have a minimum height of 300mm, except where fishing operations necessitate a reduced height. Flush hatches are to have permanently attached weathertight covers. The minimum clear opening size of any access or escape hatch is to be 500mm x 380mm.

Skylights, Portlights, Windows, etc.

.4All skylights, portlights, windows, and side scuttles, where fitted to spaces contributing to intact

buoyancy, must be to the requirements of Acceptable Construction Rules for height above deck, size, glazing thickness, and frame materials. Windows or portlights must not be fitted below the weather deck.

Ventilators and Air Pipes

.5The minimum height of any ventilator or air pipe above the weathertight deck is to be not less

than 300mm to the lowest part of the gooseneck or bend. Ventilators and air pipes terminating at less than 1.5m height above the weathertight deck must be fitted with a closing device in accordance with Acceptable Construction Rules.

Page 21 · View in original PDF